Life Safety Services - You’re Safe With Us

1-888-675-4519
  • United States
  • Canada
  • United Kingdom
  • Login
  • Home
  • Fire and Smoke Damper Services
    • Fire Damper Inspections
    • Smoke Damper Inspections
    • Fire Damper & Smoke Damper Repair
    • Fire Damper Commissioning
  • Firestop
  • Fire Doors
    • Fire Door Inspections
    • Fire Door Commissioning
  • Photoluminescence
  • Reporting
  • About Us
    • Company Info
    • Markets Served
    • GSA Contract
    • About Dampers & Doors
    • National Accounts
    • Articles
    • Press Releases
    • Resources
    • Nationwide Fire Marshals
    • Press Kit
    • Careers
    • Contact Us
    • --- Regional Operations ---
    • Central Region
      Operations
    • East North Central
      Region
    • Metropolitan New York
      City
    • Mid Atlantic Operations
    • New England Operations
    • North Western
      Operations
    • Ozarks / Gulf Coast
      Region Operations
    • Pacific Operations
    • South East Region
    • Southwestern Operations
    • Sunbelt Regional
      Operations
    • West North Central
      Region Operations
    • Western Operations
Fire Damper and Smoke Damper Inspection Services

Fire Damper Inspection and Smoke Damper Inspection Services

NFPA, The Joint Commission, ICC, and Underwriters Laboratories, Inc. require the periodic inspection of fire and smoke dampers to ensure that the dampers are operable.

This includes:

  • Operating all dampers (with fusible links removed where applicable) to verify they fully close.
  • The latch, if provided, shall be checked; and moving parts lubricated as necessary.
  • Verify the fire damper or smoke damper operation is not obstructed.
  • Verify that there is no fire damper or smoke damper interference due to rust, bent tracks, misalignment, damaged frames or blades, or defective hinges or parts.
  • If the fusible link (if applicable) is damaged or painted, it should be replaced with a link of the same size, temperature and load rating.
  • All fire and smoke damper inspections are to be documented indicating the location of the damper, date of inspection, name of the inspector and deficiencies discovered.
  • All documentation must be maintained and made available for review by the AHJ (Authority Having Jurisdiction).

(UL) Underwriters Laboratories, Inc. reminds all property owners whose buildings are equipped with fire, smoke and combination fire/smoke dampers to comply with the NFPA.

Is Your Facility in Compliance?

What will LSS Life Safety Services® do when performing Fire and Smoke Damper Inspections to allow your facility to meet these requirements?

LSS Life Safety Services® provides our clients a survey and inspection of the fire dampers and smoke dampers in their facility. Whereas many contractors only inspect the dampers listed on a set of drawings that frequently are inaccurate, LSS Life Safety Services® will perform a detailed survey of the entire facility to ensure the fire dampers and smoke dampers are located.

The fire and smoke damper inspection process will entail:

  • Locate and operate (i.e. actuate) all fire dampers and smoke dampers in the facility, removing and resetting the fusible link, to verify the damper fully closes.
  • Mark the location of the fire and smoke dampers and its corresponding number on the facility’s drawings. The damper number will coincide with the number on identification sticker that LSS Life Safety Services®’ technicians will affix to the ceiling denoting the damper location.
  • Manually activate electric smoke dampers and pneumatic smoke dampers to ensure that the actuator is operable and to verify full closure of the smoke damper.
  • In facilities such as hospitals, pharmaceutical manufactures, and research laboratories, LSS Life Safety Services®’ technicians will strictly adhere to the procedures set-forth by the facility’s safety managers. Our technicians are experienced and versed in Infection Control Procedures, the use of negative pressure containment tents, and following Healthcare Facility’s Infection Control Department’s ICRAs (Infection Control Risk Assessment) Guidelines. Additionally, LSS Life Safety Services®’ technicians have completed the 10-Hour OSHA safety training needed to work in most manufacturing facilities.

Provide third party certification report to the client

  • A Master Report Listing the location of every fire and smoke damper, the damper number, and whether the damper passed or failed inspection will be available to you and your AHJ via our web-based inspection software, LSS Site Surveyor®. If the fire or smoke damper failed the inspection, a detailed reason will be provided.
  • Summary Report providing statistical review of the fire and smoke damper inspection project. Percentages of compliant and non-compliant dampers, dampers per floor, per building, and other data is summarized and provided in report and graph format and available for you to query in multiple ways via the web.
  • Digital Documentation (i.e. Digital Picture) of every damper “Before” and “After” Inspection will be provided. Thus providing the client with photographic proof that all fire and smoke dampers were inspected, and in turn providing visual proof of the inspection to regulatory agencies (e.g. Fire Marshall, Insurance Underwriters, The Joint Commission, etc.) and internal auditors.
  • Plotting of the fire and smoke dampers on AutoCAD is also available on all projects.

Fire Damper Inspection, Smoke Damper Inspection, Fire and Smoke Damper Inspection Report
LSS Life Safety Services
® is on the GSA Federal Supply Schedule, Contract # GS-21F-0056X
GSA Contract Products:

SIN 541-099 – Fire and Smoke Damper Inspections and Repair

SIN 541-099 – Fire Door Inspections

ContractHolder_Number_psd


GSA Advantage

US Federal Contractor Registration

Contact Us

Contact Us

1-888-675-4519

  • Follow @DamperInspector
  •  
  • Life Safety Services Blog
  • Life Safety Services on YouTube

Have Questions? Click here for help

© 2013 Life Safety Services, Registration # TX7-198-218. All Rights Reserved. Privacy Policy | Sitemap.